An overview of used abbreviations can be found here: Abbreviations
Adaptive Setup since 2015
wdt_ID
Year
Binaries From
Binaries To
BICO
SA
GA1
FR
SA Ori
GA1S
Notes
FluxProcNotes
25
2016_1
2015123119.A00
2016012207.A00
D
HS50-B
IRGA72-B
B
1.30m / 0°
N-7.9 E0 V-21.3
(1)
26
2017_1
2016123119.A00
2017101107.A00
D
HS50-B
IRGA72-B
B
1.30m / 0°
N-7.9 E0 V-21.3
29
2018_1
2017123119.A00
2018123119.A00
C
HS50-B
IRGA72-B-GN1
B
1.30m / 0°
N-7.9 E0 V-21.3
(4)
30
2015_1
2015102716.A51
2015123119.A00
D
HS50-B
IRGA72-B
B
1.30m / 0°
(1) (2) not a lot of files
31
2016_2
2016012210.A51
2016123119.A00
D
HS50-B
IRGA72-B
B
1.30m / 0°
N-7.9 E0 V-21.3
32
2019_1
2018123119.A00
2019042313.A47
C
HS50-B
IRGA72-B-GN1
B
1.30m / 0°
N-7.9 E0 V-21.3
(4)
33
2019_2
2019042314.A16
2019112107.A00
B
HS50-A
IRGA72-A-GN1
A
1.30m / 0°
N-7.9 E0 V-21.3
(3) (4)
34
2017_2
2017101207.A00
2017123119.A00
C
HS50-B
IRGA72-B-GN1
B
1.30m / 0°
N-7.9 E0 V-21.3
(4)
35
2020_1
2019123119.A00
2020123119.A00
A
HS50-A
IRGA72-A
A
1.30m / 0°
N-7.9 E0 V-21.3
36
2019_3
2019112207.A00
2019123119.A00
A
HS50-A
IRGA72-A
A
1.30m / 0°
N-7.9 E0 V-21.3
(5)
37
2021_1
2020123119.A00
2021123119.A00
A
HS50-A
IRGA72-A
A
1.30m / 0°
N-7.9 E0 V-21.3
38
2022_1
2021123119.A00
2022123119.A00
A
HS50-A
IRGA72-A
A
1.30m / 0°
N-7.9 E0 V-21.3
39
2023_1
2022123119.A00
running
HS50-A
IRGA72-A
Year
Binaries From
Binaries To
BICO
SA
GA1
FR
SA Ori
GA1S
Notes
FluxProcNotes
Notes
(1) From the fieldbook: 22.01.2016 (Patrick Koller, remote): “The wrong Licor Head was installed on AWS. Thus, the data acquisition was configured for the Head 72H-0577, but the mounted head is 72H-0585! On the 22.01.2016 9:45 the appropriate configuration file was installed, Thus the fluxdata until 22.01.2016 9:45 is WRONG as it was measured using a wrong calibration. Li7200 string was wrong, after the update, could be fixed within the next two hours.” Comment LH: data also before 22 Jan 2016 looks fine to me. (2)Sonic anemometer orientation: the spar where the sonic is mounted points exactly to the north. (3) SA and GA are now containing additional output columns, similar to the extended formats at other sites, e.g. CH-DAV. (4)ISSUE: WRONG CALIBRATION GAS: There was an issue with the calibration gas used to calibrate the IRGA72. As a consequence, the CO2 concentrations in the raw data files have to be multiplied by 0.974 before flux calculations. This is done directly during the conversion of the raw data binary files to CSV files when using bico and selecting the appropriate IRGA IRGA72-B-GN1. For more info about this issue see here: Wrong Calibration Gas 2017. Affected time period: all IRGA72 CO2 concentrations between 2017101207.A00 and 2019112107.A00. (5) Data files no longer affected by calibration gas issue.
Mobile Setup 2006-2016
wdt_ID
Year
Binaries From
Binaries To
BICO
SA
GA 1
FR
SA Ori
GA1S
Notes
FluxProcNotes
3
2007_1
2007042612.b06.csv
2007091614.b07.csv
WECSV1
R2-A
IRGA75-A
1.40m / 0°
N -12 E-17 V0
(3)
4
2008_1
2008050914.b05.csv
2008100705.b01.csv
WECSV2
R2-A-EB1
IRGA75-A
1.50m / 199°
N -12 E-17 V0
(1) (3) (7)
5
2009_1
2009052014.b09
2009110411.b00
A
R2-A
IRGA75-A
1.44m / 205°
N -12 E-17 V0
10
2010_1
2010042714.b40
2010110210.b44
A
R2-A
IRGA75-A
1.50m / 34°
N -12 E-17 V0
11
2011_1
2011041814.b44
2011110810.b00
A
R2-A
IRGA75-A
1.50m / 304°
N -12 E-17 V0
13
2012_1
-
-
-
R2-A
IRGA75-A
-
N -12 E-17 V0
(2)
14
2013_1
2013042614.b38
2013110109.b30
A
R2-A
IRGA75-A
1.54m / 124°
N -12 E-17 V0
15
2014_1
2014052010.b59
2014123120.b00
A
R2-A
IRGA75-A
1.59m / 124°
N -12 E-17 V0
16
2015_1
2014123120.b00
2015123120.b00
A
R2-A
IRGA75-A
A
1.67m / 124°
N -12 E-17 V0
25
2016_1
2015123120.b00
2016090416.b50
A
R2-A
IRGA75-A
(1.67m / 124°)
N -12 E-17 V0
31
2006_1
2006060115.b00.csv
2006061420.b00.csv
WECSV1
R2-A
IRGA75-A
1.40m / ?°
N -12 E-17 V0
(4) (5) (8)
32
2006_2
2006062312.b00.csv
2006092206.b00.csv
WECSV1
R2-A
IRGA75-A
1.40m / 205°
N -12 E-17 V0
(4) (6)
Year
Binaries From
Binaries To
BICO
SA
GA 1
FR
SA Ori
GA1S
Notes
FluxProcNotes
Notes
(1) R2 has additional byte. (2) During 2012, there were timestamp issues, resulting in raw data files that have e.g. the year 2021 etc. Currently (Nov 2019) these files cannot be used because it is unknown how this timestamp error can be corrected. (3) IRGA75 data were logged in mV. Needs linear conversion to yield mmol m-3. TODO (4) Binary info currently refers to the converted raw binary files (WE). (5) Data logged @20.7 Hz in one file per hour. (6) Data logged @20.7 Hz in one file per six hours. (7) Data files now contain more raw data columns than in previous years. (8) This first data at the site should not be used, the CO2 fluxes fluctuate around zero and look off.